How to determine the surface temperature of the concrete?

The Wagner Meters Infrared Thermometer is used to test the surface temperature of the concrete. This information ensures that the user, before installation of the finished floor products, is outside the dangers of dew point and the potential for condensation formation on the surface of the concrete.

The TH-200 Thermo-Hygrometer can be used in conjunction with the Infrared Thermometer to compare the calculated dew point to the actual dew point. This comparison is important because when the surface dew point is within 5 degrees of the actual temperature, the finished floors should not be installed.